Davis Universal Anemometer Interface for Vantage Pro2 Manuale Utente Pagina 6

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 12
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 5
6
Insert the Battery
1. Insertthe3voltlithiumbatteryintothebatteryholder,matchingthe“+”sign
onthebatterywiththe“+”signinsidetheinterfaceshelter.
Note: It will take approximately one minute for the capacitor to charge and the unit to begin functioning.
Connect the Cable to the New Anemometer
R. M. Young 05103:
1. Openthejunctionboxontheanemometerandcutthejumperwire.(Its
locationismarked“JUMPFORCOMMONREF”.)
2. Unscrewthesealingnutonthestrainrelief.
3. Oneendofthe6connectorcablehasfivecoloredwires,tinnedandstripped,
andawhite(unused)wire.Feedthisendofthecablethroughthesealingnut
andthestrainreliefintothejunctionbox.
4. Connectthewirestothenumberedterminalstripasfollows:
Black . . . . . . .2
Red . . . . . . . . .3
Green . . . . . . .4
Yellow . . . . . .5
Blue . . . . . . . .6
White . . . . . . .unused
5. Replacethejunctionboxcoverandsealingnut.
NRG#40C/MAX40:
1. Useonlytheblackandbluewires.Connecttheblackwiretothe
anemometersblackgroundwireandthebluewiretotheanemometers
whitesignalwire.
2. Connecttheredandgreenwirestogether.
Vedere la pagina 5
1 2 3 4 5 6 7 8 9 10 11 12

Commenti su questo manuale

Nessun commento